MARSTEK.
Memory.
Save solar power and find the right system version for your home or balcony system.
For businesses and private customers.
Request AC memory, hybrid solutions and suitable battery extensions personally.
Availability and suitable connection version on request.

Which system are you looking for?
Select system and discover suitable devices.

Illustrative image


Illustrative image
Balcony with separate inverter
Select the SATURN memory and matching micro inverter together.

Illustrative image

Illustrative image
View all memory series → · View all MARSTEK micro inverters →
SATURN: Select memory and inverter together
SATURN as a balcony system.
The B2500-D stores solar power on the DC side. A separate micro inverter converts it for the house network. Both devices remain individually selectable.

Illustrative image
SATURN B2500-D · Memory
2,24 kWh per device. In the manufacturer's circuit up to four memory with 8,96 kWh.

Illustrative image
SATURN-M · Micro inverters
For this memory combination: the 800-W version with two MPP trackers.
The combination shown depends on the Manufacturer connection for B2500-D. Device design, cables and power limitation we vote for your system.
Model or capacity already known?
Look for a MARSTEK model, system configuration or nominal energy in kWh.
Which MARSTEK solution fits your system?
AC memory: The VENUS-E versions, VENUS G and VENUS X are guided after their documented AC coupling. PV inputs are not available for every generation. VENUS D and the own AC version are shown separately.
DC and hybrid solutions: Systems with documented PV-DC inputs can be found under DC storage systems. With MARS I PLUS, single and three-phase devices are different versions. An identical name on the battery module does not confirm interchangeability.
Integrated or separately: With integrated balcony systems, storage and inverters sit in the device. SATURN B2500-D uses a separate SATURN-M micro inverter. The documented 2-MPPT-/800-W combination is under DC; the memory is also available under batteries & extensions.
Capacity and power: Nominal energy is in kWh, inverter power in kW or kVA respectively. Usable energy is not calculated from a DoD percentage. The exact connection and power level belongs to the selection.
Manufacturer's sources: MARSTEK, Plug-in memory, Home storage systems and Original documentsSource check: 09.11.2026.
AC storage systems
Select battery and matching inverter combination together.
3 matching series in the memory archive. View archive hits ↓

MARSTEK VENUS E Pro
Expandable all-in-one system with PV inputs and AC coupling
AC system
MARSTEK VENUS E Pro · integrated AC memory version
2,08–12,48 kWh Nominal Energy
Illustrative image
CAPACITIES · VENUS E
MARSTEK VENUS E Pro
2,08–12,48 kWh Nominal Energy
English · EU version · Call 09.11.2026
- 2,08 kWh
VENUS E ProBasisgerät und 0 Erweiterungsbatterien.1 moduleDetails →Request → - 4,16 kWh
VENUS E Pro + 1 × MST-E2.0STBasisgerät und 1 Erweiterungsbatterien.2 modulesDetails →Request → - 6,24 kWh
VENUS E Pro + 2 × MST-E2.0STBasisgerät und 2 Erweiterungsbatterien.3 modulesDetails →Request → - 8,32 kWh
VENUS E Pro + 3 × MST-E2.0STBasisgerät und 3 Erweiterungsbatterien.4 modulesDetails →Request → - 10,4 kWh
VENUS E Pro + 4 × MST-E2.0STBasisgerät und 4 Erweiterungsbatterien.5 modulesDetails →Request → - 12,48 kWh
VENUS E Pro + 5 × MST-E2.0STBasisgerät und 5 Erweiterungsbatterien.6 modulesDetails →Request →
Acknowledged system combinations
- AC · MARSTEK VENUS E Pro · integrated AC memory version
Only the connections and versions described in the assigned original data sheet. Check existing PV system, measurement and connection conditions.
System design according to manufacturer documentation · 1–6 battery modules · Manufacturer's certificate
EU Prospect: 2,08 kWh in the base unit, up to five additional MST-E2.0ST batteries and 12,48 kWh in total. Four MPPT inputs with up to 2,4 kW PV; AC output 0,8/1,5 kVA after execution. Do not equate with VENUS E Mini or E 4.0.
Nominal energy (kWh) and usable energy differ. Charging/discharging power is specified in kW. Scope of delivery and system sharing for exact execution request.

MARSTEK VENUS E Max
Integrated AC storage system
AC system
MARSTEK VENUS E Max · integrated AC memory version
10,048 kWh Nominal Energy
Illustrative image
CAPACITIES · VENUS E
MARSTEK VENUS E Max
10,048 kWh Nominal Energy
English · International manufacturer's document · Retrieval 09.11.2026
- 10,048 kWh
VENUS E MaxOriginalkapazität 10,048 kWh; AC-Ausgang laut Prospekt 800 VA / 3,6 kVA.1 moduleDetails →Request →
Acknowledged system combinations
- AC · MARSTEK VENUS E Max · integrated AC memory version
Only the connections and versions described in the assigned original data sheet. Check existing PV system, measurement and connection conditions.
System design according to manufacturer documentation · 1 battery modules · Manufacturer's certificate
Original brochure mentions 10,048 kWh rated energy and AC output 800 VA / 3,6 kVA. Check the mains connection, selected power level and separate off-grid output; do not derive any other capacity from the Max model additive.
Nominal energy (kWh) and usable energy differ. Charging/discharging power is specified in kW. Scope of delivery and system sharing for exact execution request.

MARSTEK VENUS E 4.0
Generation 4.0 integrated AC storage system
AC system
MARSTEK VENUS E 4.0 · integrated AC memory version
5,024 kWh nominal energy
Illustrative image
CAPACITIES · VENUS E
MARSTEK VENUS E 4.0
5,024 kWh nominal energy
English · International manufacturer's document · Retrieval 09.11.2026
- 5,024 kWh
VENUS E 4.05.024 Wh Nennenergie; AC-Ausgang 800 VA / 3 kVA laut Original.1 moduleDetails →Request →
Acknowledged system combinations
- AC · MARSTEK VENUS E 4.0 · integrated AC memory version
Only the connections and versions described in the assigned original data sheet. Check existing PV system, measurement and connection conditions.
System design according to manufacturer documentation · 1 battery modules · Manufacturer's certificate
The original data sheet mentions 5.024 Wh and AC output 800 VA / 3 kVA. This generation has a different capacity than VENUS E 3.0 with 5,12 kWh. Do not derive useful energy from the specified DoD.
Nominal energy (kWh) and usable energy differ. Charging/discharging power is specified in kW. Scope of delivery and system sharing for exact execution request.

MARSTEK VENUS E mini
Compact integrated AC storage system
AC system
MARSTEK VENUS E mini · integrated AC memory version
2,01 kWh nominal energy
Illustrative image
CAPACITIES · VENUS E
MARSTEK VENUS E mini
2,01 kWh nominal energy
English · International manufacturer's document · Retrieval 09.11.2026
- 2,01 kWh
VENUS E MiniNennenergie rund 2,01 kWh; Herstellerangabe exakt 2.009,6 Wh.1 moduleDetails →Request →
Acknowledged system combinations
- AC · MARSTEK VENUS E mini · integrated AC memory version
Only the connections and versions described in the assigned original data sheet. Check existing PV system, measurement and connection conditions.
System design according to manufacturer documentation · 1 battery modules · Manufacturer's certificate
Nominal energy approx. 2,01 kWh; the original prospectus calls exactly 2.009,6 Wh. AC output 800 VA / 1,5 kVA. VENUS E Mini is not the 2,08-kWh base of the VENUS E Pro and does not have a battery extension described there.
Nominal energy (kWh) and usable energy differ. Charging/discharging power is specified in kW. Scope of delivery and system sharing for exact execution request.

MARSTEK VENUS D (AC Version)
Modular AC storage system without designated PV inputs
AC system
MARSTEK VENUS D (AC Version) · integrated AC memory version
2,56–15,36 kWh rated energy
Illustrative image
CAPACITIES · VENUS D
MARSTEK VENUS D (AC Version)
2,56–15,36 kWh rated energy
English · EU version · Call 09.11.2026
- 2,56 kWh
VENUS D AC-Version + 1 × MST-E2.5ST-D1 Batteriemodule gemäß Herstellerbereich.1 moduleDetails →Request → - 5,12 kWh
VENUS D AC-Version + 2 × MST-E2.5ST-D2 Batteriemodule gemäß Herstellerbereich.2 modulesDetails →Request → - 7,68 kWh
VENUS D AC-Version + 3 × MST-E2.5ST-D3 Batteriemodule gemäß Herstellerbereich.3 modulesDetails →Request → - 10,24 kWh
VENUS D AC-Version + 4 × MST-E2.5ST-D4 Batteriemodule gemäß Herstellerbereich.4 modulesDetails →Request → - 12,8 kWh
VENUS D AC-Version + 5 × MST-E2.5ST-D5 Batteriemodule gemäß Herstellerbereich.5 modulesDetails →Request → - 15,36 kWh
VENUS D AC-Version + 6 × MST-E2.5ST-D6 Batteriemodule gemäß Herstellerbereich.6 modulesDetails →Request →
Acknowledged system combinations
- AC · MARSTEK VENUS D (AC Version) · integrated AC memory version
Only the connections and versions described in the assigned original data sheet. Check existing PV system, measurement and connection conditions.
Retrofit according to system documentation · 1–6 battery modules · Manufacturer's certificate
Own AC version of the VENUS D. One to six MST-E2.5ST-D modules with 2,56 kWh each; AC output 0,8/2,5 kVA. The four PV-MPPTs of the other VENUS-D device are not assigned to this AC version.
Nominal energy (kWh) and usable energy differ. Charging/discharging power is specified in kW. Scope of delivery and system sharing for exact execution request.

MARSTEK VENUS D
Modular storage system with PV inputs and AC coupling
AC system
MARSTEK VENUS D · integrated AC memory version
2,56–15,36 kWh rated energy
Illustrative image
CAPACITIES · VENUS D
MARSTEK VENUS D
2,56–15,36 kWh rated energy
English · EU version · Call 09.11.2026
- 2,56 kWh
VENUS D + 1 × MST-E2.5ST-D1 Batteriemodule gemäß Herstellerbereich.1 moduleDetails →Request → - 5,12 kWh
VENUS D + 2 × MST-E2.5ST-D2 Batteriemodule gemäß Herstellerbereich.2 modulesDetails →Request → - 7,68 kWh
VENUS D + 3 × MST-E2.5ST-D3 Batteriemodule gemäß Herstellerbereich.3 modulesDetails →Request → - 10,24 kWh
VENUS D + 4 × MST-E2.5ST-D4 Batteriemodule gemäß Herstellerbereich.4 modulesDetails →Request → - 12,8 kWh
VENUS D + 5 × MST-E2.5ST-D5 Batteriemodule gemäß Herstellerbereich.5 modulesDetails →Request → - 15,36 kWh
VENUS D + 6 × MST-E2.5ST-D6 Batteriemodule gemäß Herstellerbereich.6 modulesDetails →Request →
Acknowledged system combinations
- AC · MARSTEK VENUS D · integrated AC memory version
Only the connections and versions described in the assigned original data sheet. Check existing PV system, measurement and connection conditions.
Retrofit according to system documentation · 1–6 battery modules · Manufacturer's certificate
Four MPPT and up to 4 kW PV input power; explicitly 2,5-kW-AC coupling in the manufacturer's description. The documented memory combination includes one to six modules with 2,56 kWh each. The table also mentions 0–6 modules; a memoryless mode of operation is not offered here as a capacity variant.
Nominal energy (kWh) and usable energy differ. Charging/discharging power is specified in kW. Scope of delivery and system sharing for exact execution request.

MARSTEK VENUS E 3.0
Integrated Generation 3.0 AC storage system
AC system
MARSTEK VENUS E 3.0 · integrated AC memory version
5,12 kWh Nominal Energy
Illustrative image
CAPACITIES · VENUS E
MARSTEK VENUS E 3.0
5,12 kWh Nominal Energy
English · EU version · Call 09.11.2026
- 5,12 kWh
VENUS E 3.0Kapazität 5,12 kWh; abweichende Nutzenergie-Angaben im Prospekt beachten.1 moduleDetails →Request →
Acknowledged system combinations
- AC · MARSTEK VENUS E 3.0 · integrated AC memory version
Only the connections and versions described in the assigned original data sheet. Check existing PV system, measurement and connection conditions.
Retrofit according to system documentation · 1 battery module · Manufacturer's certificate
EU document: 5,12 kWh capacity and AC output 800 VA / 2,5 kVA. The advertising page of the prospectus also mentions 5,12 kWh usable, while the table shows capacity and 90% DoD separately. Confirm useful energy and concrete connection before selection.
Nominal energy (kWh) and usable energy differ. Charging/discharging power is specified in kW. Scope of delivery and system sharing for exact execution request.

MARSTEK VENUS G
Modular AC storage system with V-Boost battery connection
AC system
MARSTEK VENUS G · integrated AC memory version
1–6 battery modules · rated energy on request
Illustrative image
CAPACITIES · VENUS G
MARSTEK VENUS G
1–6 battery modules · rated energy on request
English · International manufacturer's document · Retrieval 09.11.2026
- See document
VENUS G-3.6KSP + 1 × MST-VENUS G-5.0KBATNennenergie in dieser Originalunterlage nicht angegeben; Kapazität und Konfiguration anfragen.1 moduleDetails →Request → - See document
VENUS G-3.6KSP + 2 × MST-VENUS G-5.0KBATNennenergie in dieser Originalunterlage nicht angegeben; Kapazität und Konfiguration anfragen.2 modulesDetails →Request → - See document
VENUS G-3.6KSP + 3 × MST-VENUS G-5.0KBATNennenergie in dieser Originalunterlage nicht angegeben; Kapazität und Konfiguration anfragen.3 modulesDetails →Request → - See document
VENUS G-3.6KSP + 4 × MST-VENUS G-5.0KBATNennenergie in dieser Originalunterlage nicht angegeben; Kapazität und Konfiguration anfragen.4 modulesDetails →Request → - See document
VENUS G-3.6KSP + 5 × MST-VENUS G-5.0KBATNennenergie in dieser Originalunterlage nicht angegeben; Kapazität und Konfiguration anfragen.5 modulesDetails →Request → - See document
VENUS G-3.6KSP + 6 × MST-VENUS G-5.0KBATNennenergie in dieser Originalunterlage nicht angegeben; Kapazität und Konfiguration anfragen.6 modulesDetails →Request → - See document
VENUS G-4.6KSP + 1 × MST-VENUS G-5.0KBATNennenergie in dieser Originalunterlage nicht angegeben; Kapazität und Konfiguration anfragen.1 moduleDetails →Request → - See document
VENUS G-4.6KSP + 2 × MST-VENUS G-5.0KBATNennenergie in dieser Originalunterlage nicht angegeben; Kapazität und Konfiguration anfragen.2 modulesDetails →Request → - See document
VENUS G-4.6KSP + 3 × MST-VENUS G-5.0KBATNennenergie in dieser Originalunterlage nicht angegeben; Kapazität und Konfiguration anfragen.3 modulesDetails →Request → - See document
VENUS G-4.6KSP + 4 × MST-VENUS G-5.0KBATNennenergie in dieser Originalunterlage nicht angegeben; Kapazität und Konfiguration anfragen.4 modulesDetails →Request → - See document
VENUS G-4.6KSP + 5 × MST-VENUS G-5.0KBATNennenergie in dieser Originalunterlage nicht angegeben; Kapazität und Konfiguration anfragen.5 modulesDetails →Request → - See document
VENUS G-4.6KSP + 6 × MST-VENUS G-5.0KBATNennenergie in dieser Originalunterlage nicht angegeben; Kapazität und Konfiguration anfragen.6 modulesDetails →Request → - See document
VENUS G-5.0KSP + 1 × MST-VENUS G-5.0KBATNennenergie in dieser Originalunterlage nicht angegeben; Kapazität und Konfiguration anfragen.1 moduleDetails →Request → - See document
VENUS G-5.0KSP + 2 × MST-VENUS G-5.0KBATNennenergie in dieser Originalunterlage nicht angegeben; Kapazität und Konfiguration anfragen.2 modulesDetails →Request → - See document
VENUS G-5.0KSP + 3 × MST-VENUS G-5.0KBATNennenergie in dieser Originalunterlage nicht angegeben; Kapazität und Konfiguration anfragen.3 modulesDetails →Request → - See document
VENUS G-5.0KSP + 4 × MST-VENUS G-5.0KBATNennenergie in dieser Originalunterlage nicht angegeben; Kapazität und Konfiguration anfragen.4 modulesDetails →Request → - See document
VENUS G-5.0KSP + 5 × MST-VENUS G-5.0KBATNennenergie in dieser Originalunterlage nicht angegeben; Kapazität und Konfiguration anfragen.5 modulesDetails →Request → - See document
VENUS G-5.0KSP + 6 × MST-VENUS G-5.0KBATNennenergie in dieser Originalunterlage nicht angegeben; Kapazität und Konfiguration anfragen.6 modulesDetails →Request →
Acknowledged system combinations
- AC · MARSTEK VENUS G · integrated AC memory version
Only the connections and versions described in the assigned original data sheet. Check existing PV system, measurement and connection conditions.
Retrofit according to system documentation · 1–6 battery modules · Manufacturer's certificate
Prospectus introduces VENUS G-3.6KSP, -4.6KSP and -5.0KSP with one to six MST-VENUS G-5.0KBAT modules. An explicit nominal energy of the battery modules is missing in the present document. Therefore, no kWh data is derived from the model number 5.0.
Nominal energy (kWh) and usable energy differ. Charging/discharging power is specified in kW. Scope of delivery and system sharing for exact execution request.

MARSTEK VENUS X
All-in-one AC storage system with separate AC-PV input
AC system
MARSTEK VENUS X · integrated AC memory version
10–60 kWh rated energy
Illustrative image
CAPACITIES · VENUS X
MARSTEK VENUS X
10–60 kWh rated energy
English · International manufacturer's document · Retrieval 09.11.2026
- 10 kWh
VENUS XBasisgerät und 0 Erweiterungsbatterien.1 moduleDetails →Request → - 20 kWh
VENUS X + 1 × Zusatzbatterie gemäß VENUS-X-SystemBasisgerät und 1 Erweiterungsbatterien.2 modulesDetails →Request → - 30 kWh
VENUS X + 2 × Zusatzbatterie gemäß VENUS-X-SystemBasisgerät und 2 Erweiterungsbatterien.3 modulesDetails →Request → - 40 kWh
VENUS X + 3 × Zusatzbatterie gemäß VENUS-X-SystemBasisgerät und 3 Erweiterungsbatterien.4 modulesDetails →Request → - 50 kWh
VENUS X + 4 × Zusatzbatterie gemäß VENUS-X-SystemBasisgerät und 4 Erweiterungsbatterien.5 modulesDetails →Request → - 60 kWh
VENUS X + 5 × Zusatzbatterie gemäß VENUS-X-SystemBasisgerät und 5 Erweiterungsbatterien.6 modulesDetails →Request →
Acknowledged system combinations
- AC · MARSTEK VENUS X · integrated AC memory version
Only the connections and versions described in the assigned original data sheet. Check existing PV system, measurement and connection conditions.
Retrofit according to system documentation · 1–6 battery modules · Manufacturer's certificate
Original brochure: 10 kWh in the base unit, extension range 10-60 kWh and up to five additional batteries. Integrated 6-kVA inverter and up to 7,5 kVA at AC-PV input. Determine plug connections, accessories and permissible connection design according to the project.
Nominal energy (kWh) and usable energy differ. Charging/discharging power is specified in kW. Scope of delivery and system sharing for exact execution request.
No matching current series found. Change your selection or ask us personally.
The variants refer to the used system combination; further battery configurations are available in the full product view. To clarify international statements and the approval for Germany project-related. View all memory series →
Storage archive
Previous VENUS C/E versions and JUPITER C/E documents. View all archive series →
Older memory and document generations outside of this current selection. The archive assignment is not a flat-rate manufacturer termination. Replacement solutions on request.

MARSTEK VENUS E 1.0
AC memory · early VENUS-E version
AC system
Bidirectional inverter integrated in the respective VENUS device
5,12 kWh Nominal Energy
Illustrative image
ARCHIV · CAPACITIES · VENUS
MARSTEK VENUS E 1.0
5,12 kWh Nominal Energy
Original mentions VENUS-E without generation number · previous 5,12-kWh version
- 5,12 kWh
VENUS E 1.0 · früher DokumentstandNennenergie laut früherer Originalunterlage. Gerätestand bei der Archivanfrage angeben.1 moduleDetails →Archive request →
Acknowledged system combinations
- AC · Bidirectional inverter integrated in the respective VENUS device
AC-coupled design. Check the equipment stand and the corresponding original document for the concrete installation.
Retrofit according to system documentation · 1 battery module · Manufacturer's certificate
Previous VENUS-E version with 5.120 Wh according to the original data sheet. The document mentions VENUS-E without generation number; the archive name "1.0" serves to distinguish the early generation of devices. This document stands for 600 × 742 × 227 mm and 60 kg. Match equipment stand and mounting using the type plate. No data of the VENUS E 3.0 transmitted.
Nominal energy (kWh) and usable energy differ. Charging/discharging power is specified in kW. Scope of delivery and system sharing for exact execution request.

MARSTEK VENUS E 2.0
AC memory · previous generation 2.0
AC system
Bidirectional inverter integrated in the respective VENUS device
5,12 kWh Nominal Energy
Illustrative image
ARCHIV · CAPACITIES · VENUS
MARSTEK VENUS E 2.0
5,12 kWh Nominal Energy
C/E data sheet without Gen. number · supplementary original app instruction explicitly VENUS E 2.0
- 5,12 kWh
VENUS E 2.0 · MST-BIE5-2500Nennenergie laut früherer Originalunterlage. Gerätestand bei der Archivanfrage angeben.1 moduleDetails →Archive request →
Acknowledged system combinations
- AC · Bidirectional inverter integrated in the respective VENUS device
AC-coupled design. Check the equipment stand and the corresponding original document for the concrete installation.
Retrofit according to system documentation · 1 battery module · Manufacturer's certificate
Previous 5,12-kWh-VENUS-E version. The additional manufacturer app guide is explicitly referred to as "Venus E 2.0" . Data sheet and device manual use the older VENUS-E/MST-BIE5-2500 name without a unique generation number. Housing dimensions and mounting differ between these document stands; select accessories based on the type plate and equipment level. The image comes from the associated C/E device manual.
Nominal energy (kWh) and usable energy differ. Charging/discharging power is specified in kW. Scope of delivery and system sharing for exact execution request.

MARSTEK VENUS C
Integrated AC memory · previous VENUS-C/E series
AC system
Bidirectional inverter integrated in the respective VENUS device
2,56 kWh nominal energy
Illustrative image
ARCHIV · CAPACITIES · VENUS
MARSTEK VENUS C
2,56 kWh nominal energy
Original C/E brochure · VENUS-C on PDF pages 1–2
- 2,56 kWh
VENUS-C · MST-BIE2.5-2500Nennenergie laut früherer Originalunterlage. Gerätestand bei der Archivanfrage angeben.1 moduleDetails →Archive request →
Acknowledged system combinations
- AC · Bidirectional inverter integrated in the respective VENUS device
AC-coupled design. Check the equipment stand and the corresponding original document for the concrete installation.
Retrofit according to system documentation · 1 battery module · Manufacturer's certificate
Independent VENUS-C version with 2.560 Wh according to the original data sheet and manufacturer's page; type MST-BIE2.5-2500 in the manufacturer's manual. The C document mentions 450 × 550 × 200 mm and 45 kg. A separate manufacturer assignment "VENUS C 1.0/2.0" is not documented in the tested original sources; therefore the documented VENUS-C version is kept as its own archive entry.
Nominal energy (kWh) and usable energy differ. Charging/discharging power is specified in kW. Scope of delivery and system sharing for exact execution request.
No matching archived series found. Change your selection or ask us personally.
Manufacturer information about MARSTEK
MARSTEK at a glance
MARSTEK develops storage solutions for residential buildings and balcony solar systems. The manufacturer's portfolio combines integrated AC storage, modular systems and devices with its own PV inputs.
TP ENERGY merges the documented series with their original documents. Companies and private customers can request suitable devices, designs and project quantities in person.
Manufacturer's sources: MARSTEK, Plug-in memory, Home storage systems and Original documentsSource check: 09.11.2026.
Read more about MARSTEK
Which series are in this selection?
The current selection includes VENUS E Pro, E Max, E 4.0, E Mini and E 3.0, VENUS D and D AC version, JUPITER C PLUS, SATURN-C B2500, V6000, VENUS G, VENUS X and MARS I PLUS single and three-phase, MARS II and MARS I SE. VENUS E 1.0, VENUS E 2.0, VENUS C and the JUPITER C/E document generation are separated in the memory archive. Offgrid and mobile complement V500, MERCURY M1200, MERCURY M2200 and the EU version M5000-N with P5000-N.
Why do we distinguish VENUS-E generations?
The designations stand for different devices: VENUS E 3.0 calls 5,12 kWh, while E 4.0 calls 5.024 Wh. VENUS E Max calls 10,048 kWh. In the E Pro, the documented extension starts with 2,08 kWh; E Mini calls exactly 2.009,6 Wh, i.e. approximately 2,01 kWh. These values are not estimated from the model names.
How are modular systems displayed?
The variant lists connect the documented device type with the permissible number of battery modules. With the E Pro base battery and additional modules count together; with the JUPITER C PLUS up to three additional batteries are documented. For MARS I PLUS and MARS II the inverter versions are also individually named.
What information is still open?
The VENUS-G brochure mentions one to six battery modules, but no explicit rated energy. Therefore, there is no capacity derived from ‘5.0KBAT'. With VENUS E 3.0, the formulations for capacity and useful energy differ within the prospectus. We clarify such points before the concrete interpretation.
Which documents are used?
Unchanged original data sheets from the manufacturer download area are linked. EU versions are preferred; international English documents are identified as such. The verification date 09.11.2026 is the call date and no invented revision date. An international listing confirms neither inventory nor any connection execution for your project.
What's in the memory archive?
The memory archive contains VENUS E 1.0, VENUS E 2.0, VENUS C with 2,56 kWh and the previous JUPITER C/E file. Previous generation and document names are explained at the download. At VENUS C we carry out the documented execution without an unconfirmed subdivision into 1.0/2.0. The archive assignment describes our document stock and no flat-rate manufacturer termination.
Which details help with the request?
Name the exact model and generation name, desired capacity, existing PV system, inverter and connection options. For extensions help typeplate, existing modules and system status. The product action takes over the selected configuration into the central contact form.
Manufacturer's sources: MARSTEK, Plug-in memory, Home storage systems and Original documentsSource check: 09.11.2026.
Which memory fits your system?
We support you with capacity, connection design and suitable components.